HTE.PF series transmitters are specifically designed for measuring relative humidity and air temperature in poultry plants and farms where a simple, reliable, yet cost-effective solution is required. They feature high protection ratings and, if necessary, are easily repairable. Each unit undergoes 100% final quality control for operational performance and accuracy. Compatible with existing controllers from various manufacturers, due to multiple available analog output modifications.
The HTE.PF transmitter measure relative humidity and air temperature. It is optimized for indoor use where aggressive substances may be present, such as ammonia (livestock), tannins (wood drying), carbon dioxide (mushroom cultivation), and yeast (dough proofing).
All HTE.PF modifications are provided with two analogue outputs per measuring channel (voltage 0…10 V or current 4…20 mA). An RS‑485 interface with Modbus RTU is optional. Using the RS‑485 interface (HTE.PF‑xxx‑RS) you can:
Additional accessories for the HTE.PF humidity and temperature transmitters are available: mounting brackets and connection cables.
Mounting bracket HTE‑Hold is for process installation of HTE.PF transducers. HTE‑HoldW is for wall mounting; HTE‑HoldC is for duct mounting in ventilation systems. Brackets are fixed with fasteners (screws, wall plugs, etc.) through mounting holes Ø 5.5 mm.
Connection cable HTE‑Cable‑xxx is for electrical connection to HTE.PF‑xxxC (version 1.0). The cable set includes a protective cap that fits over the connector to protect contacts (for example, against disinfectant during room sanitation).
Connection cable HTE.Cable‑M12‑xxx is for electrical connection to HTE.PF‑xxxM (version 2.0).
Protective cap HTE Cap.02 is made of pressed microporous AISI 316L stainless steel. It protects the humidity sensing element from mechanical damage by small dust particles at air speeds up to 15 m/s.
Notes on using the protective cap:
| Parameter | Value |
|---|---|
| Relative humidity | |
| Readings (or measuring) range | 0 to 100% (5 to 95%) |
| Absolute error limit (at 25 °C ambient, 1 m/s airflow) | ±3% |
| Response time (63% with standard protective cap, 1 m/s airflow) | 8 s |
| Response time (95% with standard protective cap, 1 m/s airflow) | 30 s |
| Temperature | |
| Temperature measurement range (depending on modification) | -20…+80 °C -40…+ 80 °C via RS-485 interface (if available) |
| Absolute error limit | ±0.8 °С |
| Electrical characteristics | |
| Analogue output ranges * | 4…20 mA 0…10 V (0…1, 0…3, 0…5 V) |
| DC supply voltage (depends on output type) | 24 VDC ±5% (nominal value for all modifications) 12…30 VDC (4…20 mA) 6…30 VDC (0…1 V, 0…3 V or 0…5 V) 12…30 VDC (0…10 V) 5…30 VDC (digital RS-485 output) |
| Current consumption ** | 4.3 mA (for devices with current output) 3.5 mA (for devices with voltage output) 3.5 mA (for devices with RS-485) 4.5 mA (for devices with RS-485 and voltage output) |
| Allowable load resistance for current output | see Allowable load resistance of the current output |
| Minimum load for voltage output | 1 kΩ (0…1 V)
3 kΩ (0…3 V) 5 kΩ (0…5 V) 10 kΩ (0…10 V) |
| Digital output interface | RS-485 (Modbus RTU) |
| Maximum allowable cable length | 1000 m |
| Other characteristics | |
| Transmitter length (depending on modification) | 116 mm: with cable 120 mm: with connector |
| Cable length *** | 1.5 m |
| Weight (depending on modification) | 78 g: with cable 34 g: with connector |
| Ingress protection | IP67: housing IP20: sensing element |
| Transmitter materials | |
| Filter | ABS (black) |
| Housing | stainless steel AISI 304 |
| Sealing compound | silicone |
| Operating conditions | |
| Minimum air flow velocity | 1 m/s |
| Ambient temperature | -40…+80 °C |
| Permissible atmospheric pressure | 86…106 kPa |
| Ambient relative humidity | max 100% |
| Polling period (for transmitters with digital signal) | ≥ 1 s |
(*) - User configuration is possible for transmitters with RS-485 interface.
(**) - At a 24 VDC supply voltage RS-485 load is 120 Ω (without connecting analog output signals).
(***) - For modification HTE.PF with cable.
| Modifications | HTE-HoldW | HTE-HoldC |
|---|---|---|
| Plate material | stainless steel AISI304 | |
| Cable gland material | nylon | |
| Weight | 72 g | 42 g |
| Parameter | Value |
|---|---|
| Material | stainless steel AISI316L |
| Response time (63%, at 1 m/s) * | 9 s |
| Response time (95%, at 1 m/s) * | 34 s |
| Pore size | 30...45 μm |
| Ingress protection | IP65 |
* - The values are valid for the transmitter when software filtering is disabled.
| Parameter | Value |
|---|---|
| Number of pins | 8 (female) |
| Rated current | 2 А |
| Rated voltage | 30 V |
| Materials | |
| Insulation | PBT / PA (black), UL 94 V-0 |
| Contact connector | brass with gold plating |
| Nut/Screw | nickel-plated brass |
| Mechanical properties | |
| Ingress protection | IP67 |
| Wire cross section | 24 AWG / 0.25 mm² |
| Operating temperature | -40…+85 °C |
| # | Description |
|---|---|
| 1 | Power: plus (+) |
| 2 | Power: minus (-) |
| 3 | Temperature |
| 4 | Humidity |
| 5 | RS-485 B |
| 6 | RS-485 A |
| # | Description |
|---|---|
| 1 | Humidity |
| 2 | Power: minus (-) |
| 3 | Power: plus (+) |
| 4 | Temperature |
| 6 | RS-485 B |
| 7 | RS-485 A |
| # | Description |
|---|---|
| 1 | Humidity |
| 2 | Power: minus (-) |
| 3 | Power: plus (+) |
| 4 | Temperature (double) |
| 6 | Temperature (double) |
| 7 | Temperature (single) |
Attention! When connecting the device current outputs, add an external load resistor (RL) in series with the instrument’s measuring input resistor (RMEAS.). Choose RL so that the sum RMEAS. + RL stays within the permissible load range at the given supply voltage (see the external wiring diagram for HTE.PF‑I…). This reduces the influence of self-heating. For example, for a 24 VDC supply voltage, the sum of the resistances RMEAS. and RL must be between 700 Ω and 1 kΩ.