RTD temperature sensor with cable output TRL.C2

RTD temperature sensor with cable output TRL.C2

ELHART TRL.C2 series temperature sensors are resistance temperature detectors (RTDs) designed to measure the temperature of solid, liquid, and gaseous media that are non-aggressive to the protective sheath materials and sensor cable. They are used in automatic control systems for various technological processes with secondary devices (measuring instruments, controllers, input/output modules, etc.).

TRL.C2 RTDs are manufactured with platinum sensing elements Pt100 or Pt1000 and have nominal static characteristics according to GOST 6651. Upon request, the sensors can be manufactured with a cable length of 0.5, 1, 1.5 or 2.5 meters.

The protective sheath of the TRL.C2 series sensor is made of AISI 304 stainless steel.

Modifications Where to buy?

Temperature sensor TRL.C2-Pt100-0.5m
TRL.C2-Pt100-0.5m
  • Sensor type: Pt100
  • Accuracy class: B
  • Wiring configuration: 3-wire
  • Cable length: 0.5 m
Temperature sensor TRL.C2-Pt100-1.5m
TRL.C2-Pt100-1.5m
  • Sensor type: Pt100
  • Accuracy class: B
  • Wiring configuration: 3-wire
  • Cable length: 1.5 m
Temperature sensor TRL.C2-Pt100-2.5m
TRL.C2-Pt100-2.5m
  • Sensor type: Pt100
  • Accuracy class: B
  • Wiring configuration: 3-wire
  • Cable length: 2.5 m
Temperature sensor TRL.C2-Pt1000-0.5m
TRL.C2-Pt1000-0.5m
  • Sensor type: Pt1000
  • Accuracy class: B
  • Wiring configuration: 3-wire
  • Cable length: 0.5 m
Temperature sensor TRL.C2-Pt1000-1.5m
TRL.C2-Pt1000-1.5m
  • Sensor type: Pt1000
  • Accuracy class: B
  • Wiring configuration: 3-wire
  • Cable length: 1.5 m
Temperature sensor TRL.C2-Pt1000-2.5m
TRL.C2-Pt1000-2.5m
  • Sensor type: Pt1000
  • Accuracy class: B
  • Wiring configuration: 3-wire
  • Cable length: 2.5 m
  • TechnicalTechnical characteristics of TRL.C2 RTD with cable output
    Parameter Value
    Sensor type Pt100, Pt1000
    (specified upon ordering)
    Temperature coefficient of resistance (TCR) 0.00385 °C-1
    Temperature measurement range -40…+105 °C
    Accuracy class Class B:
    ±(0.3+0.005 ·|t|*) °C
    Thermal response time (63.2%) max 40 s
    Conductors copper (cross section 3×0.12 mm²)
    Conductor insulation HF (halogen-free polymer composition)
    Outer shield absent
    Jacket material HF (halogen-free polymer composition)
    Sheath material AISI304 stainless steel
    Ingress Protection IP54
    Wiring configuration 3-wire
    Electrical insulation resistance at 25 ±10 °С min 100 MΩ
    Measuring current max 1 mA (Pt100)
    max 0.3 mA (Pt1000)
    Relative air humidity up to 95%
    (without condensation)
    Mean time between failures (MTBF) min 40,000 hours
    Average service life min 10 years

    * where |t| is the absolute temperature value in °С.

  • Connection diagram of TRL.C2 temperature sensor with cable output
    Connection diagram TRL.C2 3 wires
    3-wire connection of ELHART TRL.C2 sensor
  • Overall dimensions of TRL.C2 temperature sensor with cable output
    Dimensions of ELHART TRL.C2 sensor, mm
    Dimensions of ELHART TRL.C2 sensor, mm

    L can be equal: 0.5, 1, 1.5 or 2.5 m.