Temperature sensors (thermocouples) with "bolt" type cable outlet

Temperature sensors (thermocouples) with "bolt" type cable outlet

TCE.C11 thermocouples are designed for contact measurement of solid temperatures up to +400 °C.

A distinctive feature of the sensors is the brass body, made in the form of a bolt with a movable fitting and an M6 or M8x1 thread.

Thermocouple types: J (Fe-CuNi), L (NiCr-CuNi), and K (NiCr-NiAl).

Standard modifications of TCE.C11 sensors are manufactured with 2 m cables.

Modifications Where to buy?

Temperature sensor TCE.C11-J-2-M6-L13,5-2m
TCE.C11-J-2-M6-L13,5-2m
  • Thermocouple type: J
  • Accuracy class: 2
  • Process connection: M6
  • Cable length: 2 m
Temperature sensor TCE.C11-J-2-M8-L13,5-2m
TCE.C11-J-2-M8-L13,5-2m
  • Thermocouple type: J
  • Accuracy class: 2
  • Process connection: M8
  • Cable length: 2 m
  • Technical characteristics of thermocouple with cable output TCE.C11
    Parameter Value
    Type J / L / K (specified upon ordering)
    Temperature measurement range -40…+400 °С
    Accuracy class 2
    Thermal response time (63.2%) max 20 s
    Hot junction design according to housing isolated
    Electrical insulation resistance at 25 ±10 °С min 100 MΩ
    Ingress Protection IP5X
    Sheath material brass
    Conductor insulation glass yarn
    Outer shield stainless steel (for models with M8x1 thread)
    Conductor cross-section 2×0.2 mm²
    Outer cable diameter max 2.5 mm
    Mean time between failures (MTBF) min 35,000 hours
    Service life 10 years
  • Connection diagram of TCE.C11 thermocouple
    Connection diagram of ELHART TCE.C11 sensor
    Connection diagram of ELHART TCE.C11 sensor (positive electrode is marked with a red tag)
  • Overall dimensions of TCE.C11 thermocouple
    Dimensions of ELHART TCE.C11 sensor, mm
    Dimensions of ELHART TCE.C11 sensor, mm

    For standard modifications, cable length L can be 2 m.
    Other lengths are available on request.