Thermocouple with cable output TCE.C02

Thermocouple with cable output TCE.C02

TCE.C02 thermocouples are designed for measuring the temperature of solid, granular, and gaseous media non-aggressive to the sheath and connecting cable materials.

Thermocouple types: J (Fe-CuNi), L (NiCr-CuNi), and K (NiCr-NiAl).

Standard modifications of TCE.C02 sensors are manufactured with 2 m and 5 m cables. Upon request, sensors can be manufactured with 2.5, 4, 6, 10, or 16 m cable length.

Modifications Where to buy?

Temperature sensor TCE.C02-J-2-D3-L20-1m
TCE.C02-J-2-D3-L20-1m
  • Thermocouple type: J
  • Accuracy class: 2
  • Cable length: 1 m
Temperature sensor TCE.C02-J-2-D3-L20-2m
TCE.C02-J-2-D3-L20-2m
  • Thermocouple type: J
  • Accuracy class: 2
  • Cable length: 2 m
Temperature sensor TCE.C02-J-2-D3-L20-5m
TCE.C02-J-2-D3-L20-5m
  • Thermocouple type: J
  • Accuracy class: 2
  • Cable length: 5 m
Temperature sensor TCE.C02-L-2-D3-L20-1m
TCE.C02-L-2-D3-L20-1m
  • Thermocouple type: L
  • Accuracy class: 2
  • Cable length: 1 m
Temperature sensor TCE.C02-L-2-D3-L20-2m
TCE.C02-L-2-D3-L20-2m
  • Thermocouple type: L
  • Accuracy class: 2
  • Cable length: 2 m
Temperature sensor TCE.C02-L-2-D3-L20-5m
TCE.C02-L-2-D3-L20-5m
  • Thermocouple type: L
  • Accuracy class: 2
  • Cable length: 5 m
Temperature sensor TCE.C02-K-2-D3-L20-1m
TCE.C02-K-2-D3-L20-1m
  • Thermocouple type: K
  • Accuracy class: 2
  • Cable length: 1 m
Temperature sensor TCE.C02-K-2-D3-L20-2m
TCE.C02-K-2-D3-L20-2m
  • Thermocouple type: K
  • Accuracy class: 2
  • Cable length: 2 m
Temperature sensor TCE.C02-K-2-D3-L20-5m
TCE.C02-K-2-D3-L20-5m
  • Thermocouple type: K
  • Accuracy class: 2
  • Cable length: 5 m
  • Technical characteristics of thermocouple with cable output TCE.C02
    Parameter Value
    Type J / L / K (specified upon ordering)
    Temperature measurement range -40…+400 °С
    Accuracy class 2
    Thermal response time (63.2%) max 30 s
    Hot junction design according to housing isolated
    Electrical insulation resistance at 25 ±10 °С min 100 MΩ
    Ingress Protection IP5X
    Sheath material AISI 304 stainless steel
    Conductor insulation glass yarn
    Outer jacket glass yarn
    Conductor cross-section 2×0.2 mm²
    Outer cable diameter max 2.5 mm
    Mean time between failures (MTBF) min 35,000 hours
    Service life 10 years
  • Connection diagram of TCE.C02 thermocouple
    Connection diagram of ELHART TCE.C02 sensor
    Connection diagram of ELHART TCE.C02 sensor (positive electrode is marked with a red tag)
  • Overall dimensions of TCE.C02 thermocouple
    Dimensions of ELHART TCE.C02 sensor, mm
    Dimensions of ELHART TCE.C02 sensor, mm

    For standard modifications, cable length L can be 2 or 5 m.
    Other lengths are available on request.